This glossary explains 50 terms used in ZeroHouse material. Short definitions lead to full articles and do not replace regulatory definitions.
How to read
Each term includes its other-language equivalent and a full-article link. In calculations, check units, boundary conditions and definitions in the relevant method.
Misleading shortcuts
Do not confuse kW with kWh, Uw with Ug, airtightness with no ventilation, or Listed with recommendation. These substitutions change the meaning of a technical decision.
50 terms
- Air barrier (Повітряний бар’єр)
A continuous layer with sealed joints and penetrations that controls air leakage. Read more
- Airflow rate (Витрата повітря)
Air volume per unit time; measurement location and operating mode must be specified. Read more
- Airtightness (Герметичність)
Limiting uncontrolled airflow through the envelope; not an absence of ventilation. Read more
- ATS (ATS)
Automatic source transfer under agreed logic; not a substitute for electrical design. Read more
- Blower Door (Blower Door)
A building air-leakage test using a controlled pressure difference. Read more
- BMS (BMS)
A battery-management system supervising battery condition and operating limits. Read more
- Bypass (Bypass)
An exchanger bypass under defined conditions; not active cooling generation. Read more
- Capillary transport (Капілярне перенесення)
Movement of liquid water through pores; distinct from water-vapour diffusion. Read more
- COP (COP)
Heat output divided by electrical input at specified operating conditions. Read more
- CO₂ (CO₂)
Carbon dioxide, which can indicate ventilation in an occupied room but not every pollutant. Read more
- Critical loads (Критичні навантаження)
Appliances or functions designated as priorities during an outage. Read more
- Dew point (Точка роси)
The saturation temperature for a given water-vapour content; not a fixed location in a wall. Read more
- DoD (DoD)
Depth of discharge relative to a defined battery capacity; permitted limits are product-specific. Read more
- Energy demand (Потреба енергії)
Energy over a period, distinct from instantaneous power. Read more
- Enthalpy exchanger (Ентальпійний теплообмінник)
An exchanger that can transfer some moisture as well as heat; not an active humidifier. Read more
- ETICS (ETICS)
An external thermal insulation composite system with a finish, assessed as a system. Read more
- External shading (Зовнішнє затінення)
Solar protection outside glazing; performance depends on geometry and operation. Read more
- Frost protection (Frost protection)
Ventilation-unit frost protection, with its own operational and energy effects. Read more
- g-value (g-значення)
The fraction of solar energy admitted through glazing under the assessment conditions. Read more
- Ground-bearing floor (Підлога по ґрунту)
A floor whose interaction with ground, moisture and the thermal boundary needs specific assessment. Read more
- Heat capacity (Теплоємність)
Energy required to change a body’s temperature by one kelvin; not thermal resistance. Read more
- Heat load (Теплове навантаження)
Required heating power under defined design conditions. Read more
- Inverter (Інвертор)
A power-conversion device; backup operation depends on its actual capabilities and system design. Read more
- kW (кВт)
A power unit, not battery capacity or daily energy use. Read more
- kWh (кВт·год)
An energy unit: one kilowatt sustained for one hour. Read more
- Linear transmittance ψ (Лінійний коефіцієнт ψ)
Additional heat transfer per unit junction length under the chosen dimensional convention. Read more
- Listed (Listed)
A directory profile exists; this is not certification, a guarantee or a recommendation. Read more
- Modulation (Модуляція)
Variation of equipment output within its available range to match demand. Read more
- MVHR (MVHR)
Mechanical ventilation with heat recovery and coordinated supply and extract. Read more
- n50 (n50)
Air changes due to leakage at a 50 Pa pressure difference under the test method. Read more
- Overheating (Перегрів)
An unacceptable summer temperature condition under a defined criterion, not simply a sunny window. Read more
- Passive House (Пасивний будинок)
An energy-efficient building approach and voluntary standard with defined criteria; the label alone is not certification evidence. Read more
- PHPP (PHPP)
The Passive House energy-balance planning tool; results depend on the inputs. Read more
- Plinth (Цоколь)
The lower wall zone near ground level where thermal, water and mechanical protection meet. Read more
- PV (PV)
Photovoltaic generation whose yield depends on climate, geometry and system losses. Read more
- R-value (R-значення)
Thermal resistance; units and included layers must be stated. Read more
- Relative humidity (Відносна вологість)
Water-vapour content relative to saturation at the same temperature. Read more
- SFP (SFP)
Fan electrical input relative to airflow; compare the method and units. Read more
- State of charge (Стан заряду)
An estimate of current battery reserve relative to the defined capacity. Read more
- Temperature factor (Температурний фактор)
A dimensionless relationship between internal surface, indoor and outdoor temperatures. Read more
- Thermal bridge (Тепловий міст)
A local heat-transfer variation caused by geometry or materials relative to the main planes. Read more
- Thermal conductivity λ (Теплопровідність λ)
A material’s ability to conduct heat; the design value depends on conditions. Read more
- Thermal envelope (Тепловий контур)
The boundary between temperature zones across which insulation and junctions are coordinated. Read more
- Thermal mass (Теплова маса)
The ability of assemblies to store heat and interact with temperature changes. Read more
- U-value (U-значення)
An element’s thermal transmittance, usually W/(m²·K), under a defined model. Read more
- Uf (Uf)
Frame thermal transmittance, one input to the complete-window calculation. Read more
- Ug (Ug)
Glazing thermal transmittance under defined conditions; not the whole installed-window result. Read more
- Uw (Uw)
Thermal transmittance of the complete window product, not just its glazing. Read more
- Vapour control (Пароконтроль)
Limiting vapour diffusion in a way suited to the complete assembly. Read more
- Ventilation balancing (Балансування вентиляції)
Adjustment and measurement of flows to achieve the intended room distribution. Read more
| Item | Parameter | Check / result |
|---|---|---|
| Power | kW | How much at once |
| Energy | kWh | How much over time |
| Evidence | Method and scope | What is established |
What this means for your project
Use the glossary while reading briefs and specifications. If a standard defines a term differently, its definition governs that document.